String Inverter series maximize yields of any commercial PV plant when it is connected to the low or medium-voltage grid. Maximum input voltages of up to 1000V enable longer PV strings, reducing cable losses and expenses while achieving greater energy harvests. In addition, the high power density of the inverters helps to reduce installation time and cost.
Statcon Electronics India ltd. join hands with Germany Company to manufacture State of art “Grid Tie Inverter” in India.
SolarMax 2000P | SolarMax 3000P | SolarMax 4000P | SolarMax 4600P | SolarMax 5000P | |
Input values | |||||
MPP voltage range 1) | 210.. 480 V | 310.. 480 V | 210.. 480 V | 240.. 480 V | 260.. 480 V |
Total MPP operating voltage range | 120 … 580 V | 120 … 580 V | 120 … 580 V | 120 … 580 V | 120 … 580 V |
Minimum DC voltage | 120 V | 120 V | 120 V | 120 V | 120 V |
Maximum DC voltage | 600 V | 600 V | 600 V | 600 V | 600 V |
Maximum DC current | 10 A | 10 A | 10 + 10 A | 10 + 10 A | 10 + 10 A |
Number of MPP trackers | 1 | 1 | 2 | 2 | 2 |
Number of string connections | 1 | 1 | 2 | 2 | 2 |
Connection type | Wieland PST40i1 (MC4 identical in design) | ||||
Output values | |||||
Rated output power2) | 2’000 W | 3’000 W | 4’000 W | 4’600 W | 5’000 W |
Maximum apparent output power2) | 2’000 VA | 3’000 VA | 4’000 VA | 4’600 VA | 5’000 VA |
Maximum AC current | 9 A | 13.5 A | 17.5 A | 22 A | 22 A |
Nominal mains voltage / range | 230 V / 184 .. 276 V | ||||
Mains nominal frequency / range | 50 Hz / 45 Hz…55 Hz | ||||
Power factor cos(φ) | Adjustable from 0.8 overexcited to 0.8 under excited | ||||
Distortion factor at rated output power | < 3 % | ||||
Connection type | Terminal (2.5 – 10 mm2) | ||||
Grid connection | Single phase (L / N / PE) | ||||
Power input at night | 0W | ||||
Efficiency | |||||
Maximum efficiency | 97.5 % | 97.5 % | 98.0 % | 98.0 % | 98.0 % |
Europ. Efficiency | 97.0 % | 97.0 % | 97.5 % | 97.5 % | 97.5 % |
Ambient conditions | |||||
Protection type | IP65 | ||||
Ambient temperature range (for rated power output) | -20 °C…+60 °C (+45°C) | ||||
Relative humidity | 0…100% (condensation) | ||||
Max. operating level above sea level | 2000m (without derating) | ||||
Fire protection class | V0 | ||||
Noise emissions | < 30 dB(A) (↔ 1.5 m) | ||||
Configuration | |||||
Display | Graphic LC display with backlighting and status LED | ||||
Inverter topology | HERIC®, transformer less | ||||
DC disconnector | Integrated | ||||
Data logger | Energy yield, peak output and operating hours of the last 31 days, 12 months, 10 years. Performance curves of the last 7 days. |
||||
Fault current monitoring | Internal, AC/DC sensitive | ||||
Housing / service cover | Aluminium / plastic ASA+PC | ||||
Surge protection DC and AC | Requirement class D (VDE 0675-6) and/or type 3 (EN 61643-11) | ||||
Standards & guidelines | |||||
CE-compliant | Yes | ||||
EMC | EN 61000-3-2 / EN 61000-3-3 / EN 61000-3-11 / EN 61000-3-12 / EN 61000-6-2 / EN 61000-6-3 |
||||
Grid connection | VDE 0126-1-1 A1:2012 / VDE-AR-N 41053)/ CEI 0-214) / RD 661 / RD 1699 / G83/2 / G59/2 / PPC Guide / C10/11 / EN 50438 / AS4777 |
||||
Device safety | IEC/ EN 62109-1/ -2 | ||||
Interfaces | |||||
Data communication | RS485 / Ethernet (Plug&Play) | ||||
Status signalling contact | With optional I/O module | ||||
Connection ripple control signal receiver | |||||
Connection of external lightning protection control | |||||
Connection external grid monitoring | |||||
Connection of external energy meter | |||||
Weight & dimensions | |||||
Weight | 17 kg | 17 kg | 19 kg | 19 kg | 19 kg |
Dimensions in mm (W x H x D) | 476 x 360 x 180mm | ||||
Warranty | |||||
Standard warranty | 5 years | ||||
Warranty extensions | to 10, 15, 20, or 25 years |
SolarMax 4TP | SolarMax 5TP2 | SolarMax 6TP2 | SolarMax 7TP2 | |
Input values | ||||
MPP-voltage range 1) | 420 … 750 V | 260 … 750 V | 310 … 750 V | 360 … 750 V |
Control range | 250 … 840V | 250 … 840V | 250 … 840V | 250 … 840V |
Minimum DC voltage | 250 V | 250 V | 250 V | 250 V |
Maximum DC voltage | 900 V | 900 V | 900 V | 900 V |
Maximum DC current | 10 A | 10 + 10 A | 10 + 10 A | 10 + 10 A |
Number of MPP-Trackers | 1 | 2 | 2 | 2 |
Maximum PV generator output power per MPPT | 5’000 Wp | 5’000 Wp | 5’000 Wp | 5’000 Wp |
Number of string connections | 1 | 2 | 2 | 2 |
Connection type | Wieland PST40i1 (identical to MC4) | |||
Output values | ||||
Rated output power2) | 4’000 W | 5’000 W | 6’000 W | 7’000 W |
Maximum apparent output power2) | 4’000 VA | 5’000 VA | 6’000 VA | 7’000 VA |
Maximum AC current | 3 x 6.5 A | 3 x 7.5 A | 3 x 9.5 A | 3 x 10.2 A |
Nominal mains voltage | 3 x 400 V | |||
Mains nominal frequency / range | 50 Hz / 45 Hz…55 Hz | |||
Power factor cos(φ) | Adjustable from 0.8 overexcited to 0.8 under excited | |||
Distortion factor at rated output power | < 3 % | |||
Connection type | Terminal(2.5 – 10 mm2) | |||
Grid connection | Three-phase (L1 / L2 / L3 / N / PE) | |||
Power input at night | < 0.1 W | |||
Efficiency | ||||
Max. efficiency | 97.5 % | 97.6 % | 97.6 % | 97.6 % |
Euro efficiency | 96.0 % | 96.5 % | 96.6 % | 96.7 % |
Ambient conditions | ||||
Protection class | IP65 | |||
Ambient temperature range (for rated power output) | -20 °C…+60 °C (+45°C) | |||
Relative humidity | 0…100% (condensation) | |||
Maximum operating level above sea level | 2000m | |||
Fire protection class | UL94 V0 | |||
Configuration | ||||
Display | LC graphics display with backlighting and status LED | |||
Inverter topology | transformer less | |||
DC disconnector | integrated | |||
Data logger | Energy yield, peak output, and operating duration of the last 31 days, 12 months, 10 years. Performance curves of the last 7 days. |
|||
Fault current monitoring | Internal, AC/DC sensitive | |||
Housing / service cover | Aluminium / plastic ASA+PC | |||
Overvoltage conductor, DC and AC | Requirement class D (VDE 0675-6) and/or type 3 (EN 61643-11) | |||
Standards & guidelinesn | ||||
EMC | EN 61000-3-2 / EN 61000-3-3 / EN 61000-6-2 / EN 61000-6-3 | |||
Grid connection | VDE 0126-1-1 (A1:2012/ 2013) / VDE-AR-N 4105 / UTE C15-712-1 / E8001-4-712 |
|||
Device safety | IEC/ EN 62109-1/ -2 | |||
Interfaces | ||||
Data communication | RS485 / Ethernet (Plug&Play) | |||
Status signaling contact | integrated | |||
Connection ripple control signal receiver | integrated | |||
Connection lightning protection monitor | integrated | |||
Connection to external grid monitoring | integrated | |||
Connection to external energy counter | S0 | |||
Gewicht & Abmessungen | ||||
Weight | 20 kg | 21 kg | 21 kg | 21 kg |
Dimensions (W x H x D) | 476 x 360 x 180 mm | |||
Warranty | ||||
Standard warranty | 5 years | |||
Warranty extensions | to10, 15, 20 or 25 years |
8MT2 | 10MT2 | 13MT2 | 15MT2 | 13MT3 | 15MT3 | ||
Input values | MPP-voltage range 1) | 300 … 750 V | 290 … 750 V | 370 … 750 V | 430 … 750 V | 280 … 750 V | 320… 750 V |
Control range | 250 … 750 V | ||||||
Minimum DC-voltage | 250 V | ||||||
Maximum DC-voltage | 900 V | ||||||
Maximum DC-current | 1 x 18A/1 x 9A | 2 x 18 A | 2 x 18 A | 2 x 18 A | 3 x 16 A | 3 x 16 A | |
Number of MPP-Trackers | 2 | 3 | |||||
Max. PV generator output power per MPP tracker |
MPPT 1 9.000 Wp MPPT2: 5.000 Wp |
9.000 Wp | |||||
Number of string connections | 1 x 2 / 1 x 1 | 2 x 2 | 3 x 2 | ||||
Connection type | MC 4 | ||||||
Output values | Rated output power 2) | 8.000 W | 10.000 W | 13.000 W | 15.000 W | 13.000 W | 15.000 W |
Maximum apparent output power 2) | 8.000 VA | 10.000 VA | 13.000 VA | 15.000 VA | 13.000 VA | 15.000 VA | |
Maximum AC current | 3 x 12 A | 3 x 16 A | 3 x 20 A | 3 x 22 A | 3 x 20 A | 3 x 22 A | |
Nominal mains voltage | 3 x 400 V | ||||||
Mains nominal frequency / range | 50 Hz / 45 Hz … 55 Hz | ||||||
Power factor cos (φ) | Adjustable from 0.8 overexcited to 0.8 under excited | ||||||
Distortion factor at rated output power | < 3 % | ||||||
Connection type | Connector (locking) | ||||||
Grid connection | Three phase (L1 / L2 / L3 / N / PE) | ||||||
Power input at night | 0 W | ||||||
Efficiency | Max. efficiency | 98.0 % | |||||
Euro efficiency | 97.5 % | ||||||
Ambient conditions | Protection class | IP65 | |||||
Ambient temperature range (for rated power output) | -20°C … + 60°C (+50°C) | ||||||
Relative humidity | 0 … 98 % (condensation) | ||||||
Maximum operating level above sea level | 2.000 m (without derating) | ||||||
Fire protection | According EN 62109-1/ -2 | ||||||
Noise emissions (1,5 m) | 51 dBA (fan off) / 58 dBA (fan on) | ||||||
Configuration | Display | LC graphics display with backlighting and status LED | |||||
Circuit type | Two-stage, transformer less | ||||||
DC disconnector | Integrated | ||||||
Data logger | Data logger for Energy yield, peak output, and operating duration of the last 31 days, 12 months, 10 years. | ||||||
Fault current monitoring | Internal, AC/DC sensitive | ||||||
Casing | Aluminum | ||||||
Overvoltage conductor DC | Requirement class C (VDE 0675-6) and/or type 2 (EN 61643-11) | ||||||
Overvoltage conductor AC | Requirement class D (VDE 0675-6) and/or type 3 (EN 61643-11) | ||||||
Standard & guidelines | EMC | EN 61000-3-2 / EN 61000-3-3 / EN 61000-3-11 / EN 61000-3-12 / EN 61000-6-2 / EN 61000-6-3 | |||||
Grid connection | VDE 0126-1-1 A1:2012 / VDE-AR-N 4105 / BDEW MS-Richtlinie / G59/2 / CEI 0-21 / CEI 0-16 / RD 1699 G83/2 / PPC Guide / C10/11 / EN 50438 / AS 4777 | ||||||
Device safety | EN 62109-1/ -2 | ||||||
Interfaces | Data communication | RS485 / Ethernet | |||||
Status signaling contact | M12 connector with relay as N/C contact / N/O contact | ||||||
Connection ripple control signal receiver | With MaxRemote | ||||||
Connection external grid monitoring | M12 Connector | ||||||
Weight & Dimensions | Weight | 39 kg | 42 kg | ||||
Dimensions (W x H x D) | 550 x 750 x 200 mm | ||||||
Warranty | Standard warranty | 5 years | |||||
Warranty extensions | to10, 15, 20 or 25 years |
30HT4 | 32HT4 | 32HT2 | |
Input values | |||
MPP-voltage range 1) | 430…850 V 4) | 460…850 V 4) | 460…850 V 4) |
Minimum DC voltage | 250 V | ||
Maximum DC voltage | 1000 V | ||
Maximum DC current | 4 x 18 A | 2 x 36 A | |
Number of MPP trackers | 4 | 2 | |
Max. PV generator output power per MPP tracker 6) | 9,000 W | 18,000 W | |
Number of string connections | 4 x 2 | 2 x 4 2) | |
Connector type | Wieland PST40i1 (MC4 identical in design) | ||
Output values | |||
Rated output power | 30,000 W | 32,000 W | 32,000 W |
Maximum apparent output power | 30,000 VA | 32,000 VA | 32,000 VA |
Nominal mains voltage | 3 x 400 V | ||
Maximum AC current | 3 x 44 A | 3 x 47 A | 3 x 47 A |
Mains nominal frequency / range | 50 Hz / 45 Hz…55 Hz | ||
Power factor cos(φ) | Adjustable from 0.8 overexcited to 0.8 under excited | ||
Distortion factor at rated output power | < 3% | ||
Connection type | Screw terminal | ||
Grid connection | Three-phase (L1 / L2 / L3 / N / PE) | ||
Power input at night | 0VA 3) | ||
Efficiency | |||
Max. efficiency | 98.0% | ||
Euro efficiency | 97.5% | ||
Ambient conditions | |||
Protection class | IP 65 | ||
Ambient temperature range (for rated power output) | -20°C…+60°C (+45°C) | ||
Relative humidity | 0…100% (condensation) | ||
Maximum altitude above sea level | 2000m (without derating) | ||
Configuration | |||
Display | LC graphics display with backlighting and status LED | ||
Circuit type | Two-stage, transformer less | ||
DC disconnector | Integrated | Integrated | No, 2x in optional connection box |
Data logger | Data logger for energy yield, peak output, and operating duration for the last 31 days, 12 months and 10 years | ||
Fault current monitoring | Internal, AC/DC-sensitive | ||
Casing | Aluminium | ||
Overvoltage conductor DC | Class C (VDE 0675-6) and type 2 (EN 61643-11) | Class C (VDE 0675-6) and type 2 (EN 61643-11) / surge arrester type I/II in the connection box | |
Overvoltage conductor AC | Class D (VDE 0675-6) and type 3 (EN 61643-11) | ||
Standards & guidelines 4) | |||
EMC | EN 61000-3-11 / EN 61000-3-12 / EN 61000-6-2 / EN 61000-6-3 | ||
Grid connection | VDE-AR-N 4105 / VDE 0126-1-1 A1:2012 / BDEW MV directive / G59/3 / CEI 0-21 / CEI 0-16 / PPC Guide / C10/11 / EN 50438 | ||
Device safety | IEC 62109-1/-2 | ||
Interfaces | |||
Data communication | RS485 (RJ45 and terminal screw) / Ethernet (RJ45) | ||
Status signalling contact | Relay as N/C contact / N/O contact (terminal screw) | ||
Connection to external grid monitoring | Terminal screw | ||
Weight & dimensions | |||
Weight | 70 kg | 70 kg 5) | |
Dimensions in mm (W x H x D) | 580 x 840 x 380 | 580 x 840 x 380 5) | |
Warranty | |||
Standard warranty | 5 years | ||
Warranty extension | to 10, 15, 20, or 25 years |
EQUIPMENT | DESCRIPTION | QTY |
Internet – capable Data logger | MaxWeb xp is a data logger and the essential hub for remote photovoltaic system monitoring. It records current measured values, yield data, and events and transmits these to our Statcon Portal. | 1 No. |
Statcon Portal | System data can be accessed from anywhere via the Internet | 1 No. |
Max Talk Pro | With just a few clicks you can install MaxTalk 2 on your PC. Connected to the inverter via Ethernet or RS485, the user-friendly program immediately displays important yield and measured values. | 1 No. |
CE