Grid Tie Inverter / String Inverter:

String Inverter series maximize yields of any commercial PV plant when it is connected to the low or medium-voltage grid. Maximum input voltages of up to 1000V enable longer PV strings, reducing cable losses and expenses while achieving greater energy harvests. In addition, the high power density of the inverters helps to reduce installation time and cost.
Statcon Electronics India ltd. join hands with Germany Company to manufacture State of art “Grid Tie Inverter” in India.

  • The high power density of the inverters help to reduce installation time and cost.
  • The robust NEMA 4X aluminum housing can withstand extremely challenging weather conditions.
  • Multi – MPPT concept means no string fuses are required to protect DC lines.
  • The Multi-MPPT concept of the MTA series reduces the distance between the module rows allowing better ground coverage ratio.
  • Different irradiation conditions or asymmetrical divisions of the PV strings can be adopted.

 P-Series

  SolarMax 2000P SolarMax 3000P SolarMax 4000P SolarMax 4600P SolarMax      5000P
Input values
MPP voltage range 1) 210.. 480 V 310.. 480 V 210.. 480 V 240.. 480 V 260.. 480 V
Total MPP operating voltage range 120 … 580 V 120 … 580 V 120 … 580 V 120 … 580 V 120 … 580 V
Minimum DC voltage 120 V 120 V 120 V 120 V 120 V
Maximum DC voltage 600 V 600 V 600 V 600 V 600 V
Maximum DC current 10 A 10 A 10 + 10 A 10 + 10 A 10 + 10 A
Number of MPP trackers 1 1 2 2 2
Number of string connections 1 1 2 2 2
Connection type Wieland PST40i1 (MC4 identical in design)
Output values
Rated output power2) 2’000 W 3’000 W 4’000 W 4’600 W 5’000 W
Maximum apparent output power2) 2’000 VA 3’000 VA 4’000 VA 4’600 VA 5’000 VA
Maximum AC current 9 A 13.5 A 17.5 A 22 A 22 A
Nominal mains voltage / range 230 V / 184 .. 276 V
Mains nominal frequency / range 50 Hz / 45 Hz…55 Hz
Power factor cos(φ) Adjustable from 0.8 overexcited to 0.8 under excited
Distortion factor at rated output power < 3 %
Connection type Terminal (2.5 – 10 mm2)
Grid connection Single phase (L / N / PE)
Power input at night 0W
Efficiency
Maximum efficiency 97.5 % 97.5 % 98.0 % 98.0 % 98.0 %
Europ. Efficiency 97.0 % 97.0 % 97.5 % 97.5 % 97.5 %
Ambient conditions
Protection type IP65
Ambient temperature range (for rated power output) -20 °C…+60 °C (+45°C)
Relative humidity 0…100% (condensation)
Max. operating level above sea level 2000m (without derating)
Fire protection class V0
Noise emissions < 30 dB(A) (↔ 1.5 m)
Configuration
Display Graphic LC display with backlighting and status LED
Inverter topology HERIC®, transformer less
DC disconnector Integrated
Data logger Energy yield, peak output and operating hours of the last 31 days, 12 months, 10 years.
Performance curves of the last 7 days.
Fault current monitoring Internal, AC/DC sensitive
Housing / service cover Aluminium / plastic ASA+PC
Surge protection DC and AC Requirement class D (VDE 0675-6) and/or type 3 (EN 61643-11)
Standards & guidelines
CE-compliant Yes
EMC EN 61000-3-2 / EN 61000-3-3 / EN 61000-3-11 / EN 61000-3-12 / EN 61000-6-2 /
EN 61000-6-3
Grid connection VDE 0126-1-1 A1:2012 / VDE-AR-N 41053)/ CEI 0-214) / RD 661 / RD 1699 / G83/2 /
G59/2 / PPC Guide / C10/11 / EN 50438 / AS4777
Device safety IEC/ EN 62109-1/ -2
Interfaces
Data communication RS485 / Ethernet (Plug&Play)
Status signalling contact With optional I/O module
Connection ripple control signal receiver
Connection of external lightning protection control
Connection external grid monitoring
Connection of external energy meter
Weight & dimensions
Weight 17 kg 17 kg 19 kg 19 kg 19 kg
Dimensions in mm (W x H x D) 476 x 360 x 180mm
Warranty
Standard warranty 5 years
Warranty extensions to 10, 15, 20, or 25 years

TP Series

  SolarMax 4TP SolarMax 5TP2 SolarMax 6TP2 SolarMax 7TP2
Input values
MPP-voltage range 1) 420 … 750 V 260 … 750 V 310 … 750 V 360 … 750 V
Control range 250 … 840V 250 … 840V 250 … 840V 250 … 840V
Minimum DC voltage 250 V 250 V 250 V 250 V
Maximum DC voltage 900 V 900 V 900 V 900 V
Maximum DC current 10 A 10 + 10 A 10 + 10 A 10 + 10 A
Number of MPP-Trackers 1 2 2 2
Maximum PV generator output power per MPPT 5’000 Wp 5’000 Wp 5’000 Wp 5’000 Wp
Number of string connections 1 2 2 2
Connection type Wieland PST40i1 (identical to MC4)
Output values
Rated output power2) 4’000 W 5’000 W 6’000 W 7’000 W
Maximum apparent output power2) 4’000 VA 5’000 VA 6’000 VA 7’000 VA
Maximum AC current 3 x 6.5 A 3 x 7.5 A 3 x 9.5 A 3 x 10.2 A
Nominal mains voltage 3 x 400 V
Mains nominal frequency / range 50 Hz / 45 Hz…55 Hz
Power factor cos(φ) Adjustable from 0.8 overexcited to 0.8 under excited
Distortion factor at rated output power < 3 %
Connection type Terminal(2.5 – 10 mm2)
Grid connection Three-phase (L1 / L2 / L3 / N / PE)
Power input at night < 0.1 W
Efficiency
Max. efficiency 97.5 % 97.6 % 97.6 % 97.6 %
Euro efficiency 96.0 % 96.5 % 96.6 % 96.7 %
Ambient conditions
Protection class IP65
Ambient temperature range (for rated power output) -20 °C…+60 °C (+45°C)
Relative humidity 0…100% (condensation)
Maximum operating level above sea level 2000m
Fire protection class UL94 V0
Configuration
Display LC graphics display with backlighting and status LED
Inverter topology transformer less
DC disconnector integrated
Data logger Energy yield, peak output, and operating duration of the last 31 days, 12 months, 10 years.
Performance curves of the last 7 days.
Fault current monitoring Internal, AC/DC sensitive
Housing / service cover Aluminium / plastic ASA+PC
Overvoltage conductor, DC and AC Requirement class D (VDE 0675-6) and/or type 3 (EN 61643-11)
Standards & guidelinesn
EMC EN 61000-3-2 / EN 61000-3-3 / EN 61000-6-2 / EN 61000-6-3
Grid connection VDE 0126-1-1 (A1:2012/ 2013) / VDE-AR-N 4105 /
UTE C15-712-1 / E8001-4-712
Device safety IEC/ EN 62109-1/ -2
Interfaces
Data communication RS485 / Ethernet (Plug&Play)
Status signaling contact integrated
Connection ripple control signal receiver integrated
Connection lightning protection monitor integrated
Connection to external grid monitoring integrated
Connection to external energy counter S0
Gewicht & Abmessungen
Weight 20 kg 21 kg 21 kg 21 kg
Dimensions (W x H x D) 476 x 360 x 180 mm
Warranty
Standard warranty 5 years
Warranty extensions to10, 15, 20 or 25 years

MT series

8MT2 10MT2 13MT2 15MT2 13MT3 15MT3
Input values MPP-voltage range 1) 300 … 750 V 290 … 750 V 370 … 750 V 430 … 750 V 280 … 750 V 320… 750 V
Control range 250 … 750 V
Minimum DC-voltage                                 250 V
Maximum DC-voltage 900 V
Maximum DC-current 1 x 18A/1 x 9A 2 x 18 A 2 x 18 A 2 x 18 A 3 x 16 A 3 x 16 A
Number of MPP-Trackers                                2                 3
Max. PV generator output power per MPP tracker

MPPT 1 9.000 Wp

MPPT2: 5.000 Wp

                               9.000 Wp
Number of string connections 1 x 2 / 1 x 1 2 x 2 3 x 2
Connection type                                      MC 4
Output values Rated output power 2) 8.000 W 10.000 W 13.000 W 15.000 W 13.000 W 15.000 W
Maximum apparent output power 2) 8.000 VA 10.000 VA 13.000 VA 15.000 VA 13.000 VA 15.000 VA
Maximum AC current 3 x 12 A 3 x 16 A 3 x 20 A 3 x 22 A 3 x 20 A 3 x 22 A
Nominal mains voltage 3 x 400 V
Mains nominal frequency / range 50 Hz / 45 Hz … 55 Hz
Power factor cos (φ) Adjustable from 0.8 overexcited to 0.8 under excited
Distortion factor at rated output power < 3 %
Connection type Connector (locking)
Grid connection Three phase (L1 / L2 / L3 / N / PE)
Power input at night 0 W
Efficiency Max. efficiency 98.0 %
Euro efficiency 97.5 %
Ambient conditions Protection class IP65
Ambient temperature range (for rated power output) -20°C … + 60°C (+50°C)
Relative humidity 0 … 98 % (condensation)
Maximum operating level above sea level 2.000 m (without derating)
Fire protection According EN 62109-1/ -2
Noise emissions (1,5 m) 51 dBA (fan off) / 58 dBA (fan on)
Configuration Display LC graphics display with backlighting and status LED
Circuit type Two-stage, transformer less
DC disconnector Integrated
Data logger Data logger for Energy yield, peak output, and operating duration of the last 31 days, 12 months, 10 years.
Fault current monitoring Internal, AC/DC sensitive
Casing Aluminum
Overvoltage conductor DC Requirement class C (VDE 0675-6) and/or type 2 (EN 61643-11)
Overvoltage conductor AC Requirement class D (VDE 0675-6) and/or type 3 (EN 61643-11)
Standard & guidelines EMC EN 61000-3-2 / EN 61000-3-3 / EN 61000-3-11 / EN 61000-3-12 / EN 61000-6-2 / EN 61000-6-3
Grid connection VDE 0126-1-1 A1:2012 / VDE-AR-N 4105 / BDEW MS-Richtlinie / G59/2 / CEI 0-21 / CEI 0-16 / RD 1699 G83/2 / PPC Guide / C10/11 / EN 50438 / AS 4777
Device safety EN 62109-1/ -2
Interfaces Data communication RS485 / Ethernet
Status signaling contact M12 connector with relay as N/C contact / N/O contact
Connection ripple control signal receiver With MaxRemote
Connection external grid monitoring M12 Connector
Weight & Dimensions Weight 39 kg 42 kg
Dimensions (W x H x D) 550 x 750 x 200 mm
Warranty Standard warranty 5 years
Warranty extensions to10, 15, 20 or 25 years

HT series

  30HT4 32HT4 32HT2
Input values
MPP-voltage range 1) 430…850 V 4) 460…850 V 4) 460…850 V 4)
Minimum DC voltage 250 V
Maximum DC voltage 1000 V
Maximum DC current 4 x 18 A 2 x 36 A
Number of MPP trackers 4 2
Max. PV generator output power per MPP tracker 6) 9,000 W 18,000 W
Number of string connections 4 x 2 2 x 4 2)
Connector type Wieland PST40i1 (MC4 identical in design)
Output values
Rated output power 30,000 W 32,000 W 32,000 W
Maximum apparent output power 30,000 VA 32,000 VA 32,000 VA
Nominal mains voltage 3 x 400 V
Maximum AC current 3 x 44 A 3 x 47 A 3 x 47 A
Mains nominal frequency / range 50 Hz / 45 Hz…55 Hz
Power factor cos(φ) Adjustable from 0.8 overexcited to 0.8 under excited
Distortion factor at rated output power < 3%
Connection type Screw terminal
Grid connection Three-phase (L1 / L2 / L3 / N / PE)
Power input at night 0VA 3)
Efficiency
Max. efficiency 98.0%
Euro efficiency 97.5%
Ambient conditions
Protection class IP 65
Ambient temperature range (for rated power output) -20°C…+60°C (+45°C)
Relative humidity 0…100% (condensation)
Maximum altitude above sea level 2000m (without derating)
Configuration
Display LC graphics display with backlighting and status LED
Circuit type Two-stage, transformer less
DC disconnector  Integrated  Integrated  No, 2x in optional connection box
Data logger Data logger for energy yield, peak output, and operating duration for the last 31 days, 12 months and 10 years
Fault current monitoring Internal, AC/DC-sensitive
Casing Aluminium
Overvoltage conductor DC Class C (VDE 0675-6) and type 2 (EN 61643-11) Class C (VDE 0675-6) and type 2 (EN 61643-11) / surge arrester type I/II in the connection box
Overvoltage conductor AC Class D (VDE 0675-6) and type 3 (EN 61643-11)
Standards & guidelines 4)
EMC EN 61000-3-11 / EN 61000-3-12 / EN 61000-6-2 / EN 61000-6-3
Grid connection VDE-AR-N 4105 / VDE 0126-1-1 A1:2012 / BDEW MV directive / G59/3 / CEI 0-21 / CEI 0-16 / PPC Guide / C10/11 / EN 50438
Device safety IEC 62109-1/-2
Interfaces
Data communication RS485 (RJ45 and terminal screw) / Ethernet (RJ45)
Status signalling contact Relay as N/C contact / N/O contact (terminal screw)
Connection to external grid monitoring Terminal screw
Weight & dimensions
Weight 70 kg 70 kg 5)
Dimensions in mm (W x H x D) 580 x 840 x 380 580 x 840 x 380 5)
Warranty
Standard warranty 5 years
Warranty extension to 10, 15, 20, or 25 years
EQUIPMENT DESCRIPTION QTY
Internet – capable Data logger MaxWeb xp is a data logger and the essential hub for remote photovoltaic system monitoring. It records current measured values, yield data, and events and transmits these to our Statcon Portal. 1 No.
Statcon Portal System data can be accessed from anywhere via the Internet 1 No.
Max Talk Pro With just a few clicks you can install MaxTalk 2 on your PC. Connected to the inverter via Ethernet or RS485, the user-friendly program immediately displays important yield and measured values. 1 No.

CE
TUB