STATIC FREQUENCY CONVERTER :
Present day aircrafts dominantly use electrical power. It is normally 115V, 3 Phase, 400Hz which is converted from 415V, 3 Phase, 50 Hz supply.
It is suitable for motor load and is transformed and rectified to various levels for use in avionics loads. Its nature and quality is specified by Mil-std 704. Statcon Electronics product is based on technology from Statcon Power Controls Ltd are fully compliant with these requirements.

  • Proven design
  • Wide input range
  • Very stable output voltage
  • Stable output frequency
  • Fast transient recovery
  • low noise & EMI / RFI
  • Available in 1 & 3 Phase Input and Output
  • Available up to 100KVA
Electrical 3 Ph. To 3 Ph. 3 Ph. To 1 Ph.
Rating As per customer’s requirement As per customer’s requirement
Input Voltage range 400V±10% AC 400V±10% AC
Input Frequency range 50Hz±5% 50Hz±5%
Phase Three Three
Power Factor 0.8 lagging 0.8 lagging
Output Particulars
Voltage range 208V AC 115V AC
Power Factor 0.8 lag 0.8 lag
Output Frequency 400Hz. 400Hz.
Output Phase Three Single
Frequency Stability ±1% ±1%
Frequency Regulation <±1% <±1%
Phase Difference 120°±2° 180°±2°
Voltage Regulation ±1% ±1%
Voltage Transient Max 20% of the set value and restores within 0.5sec, for step load charge of 25% to 75% <5% of the rated continuous Load.
Crest Factor 1.31 to 1.51 1.414±3%
Total Harmonic Content RMS content of the THD<5% of the fundamental rms voltage for load between 50%, -100% RMS content of the THD<5% of the fundamental rms voltage for load between 50%, -100%
Over Load Capacity 150% for 5 sec, 125% for 5 min, 110% for 50 min. 150% for 5 sec, 125% for 5 min, 110% for 50 min.
Display/Metering
AC Voltage This shows three-phase input voltage This shows three-phase input voltage
Output Voltage This shows output three phase voltage This shows output single phase voltage
Output Current This shows output load current This shows output load current
Output Frequency This shows frequency of the output This shows frequency of the output
Input under Voltage Input voltage less than specified range Input voltage less than specified range
Input Over Voltage Input voltage greater than specified range Input voltage greater than specified range
Output Over Voltage Output voltage greater than specified set voltage Output voltage greater than specified set voltage
Output Under Voltage Output voltage less than specified set voltage Output voltage less than specified set voltage
Output Over Frequency Output frequency less than specified set frequency Output frequency less than specified set frequency
Mechanical
Installation Indoor in a well ventilated area or outdoor under the shade away from direct sunlight and heat.
Enclosure Sheet metal enclosed, floor mounted or trolley mounted
Degree of Protection IP-31 to IP-52
Colour shade RAL-7032 Siemens grey or on demand.
Climatic
Ambient temperature -20°C to 55°C
Humidity Max. 95% at 40°C
Altitude Upto 1000 meter above MSL